I tried replacing the bulbs and it continued to do the same thing. These new connectors also have a little different wire push connection. The old T12 tube (1.5" diameter) is obsolete. But read carefully, because there are safety concerns. If you can change out a light switch or outlet you can definitely replace an old ballast that doesn’t work. Try not to ruin or mangle the staple you will be reusing it. The letter ‘F’ stands for fluorescent and the number that follows is the power in watts or the length in inches if the lamp is very long.The letter ‘T’ means that the bulb is a tubular shape. Click to see full answer. 5 the pins are spaced identically so when changing from T12 to T8, you would not need to change the tombstones. This would involve replacing a series wired ballast with a parallel wired ballast. A typical application operates lights for 4,000 hours per year. Right now, a ballast-bypass is our top LED replacement option for T12 fluorescent tubes. As with all projects, I like to start by snapping a few pictures of how the old fixture was laid out before starting to disassemble. Most T12 sizes have a T8 (1" diameter) equivalent which will snap right in, but is not electrically compatible. Remove The Ballast Now, you must take out the ballast by unscrewing it. Remove the wire nuts from the black and white wires connecting the ballast to the electrical circuit. Or, you can read the printing on the tube to identify the correct replacement type. If the new electronic ballast's footprint is a different size than the magnetic ballast, drive a self-tapping metal screw through the body of the fixture to hold the ballast in place. But read carefully, because there are safety concerns. But you've probably figured that out by now. Replace the fluorescent light ballast in four steps. T12 electronic ballasts are 20 percent more energy efficient than the magnetic technology that it replaces. Then, fix the new T8 fluorescent tube light, and that’s all. It shows the elements of the circuit as simplified forms, and also the power and also signal connections in between the tools. The old ballast has the black and white wires on one side and a blue and a red wire on the other side. If an old T12 lamp magnetic ballast is replaced with a newer T8 lamp and electronic ballast, the colors will probably not match. T12 Ballast Wiring Diagram. This would involve replacing a.iBallast has the largest selection of fluorescent ballasts, metal halide ballasts, high pressure sodium ballasts and dimming ballast. The higher frequencies produced by an electronic ballast create 10 to 12 percent more light output than the magnetic ballast operating a T12 … Locate your ballast. To purchase a new 300mm led tube replacement see our fluorescent tubes section. Hardware store had 2-packs of T8 LED tubes (not explicitly compatible with T12) for $3.75, so I wonder about the electrical stress on these T8s in a T12 fixture. This is because the wire colors on the ballast and the lampholders do not match up on two of the connections. It is for a 2 bulb T12 or T8 fixture. This would involve replacing a series wired ballast with a parallel wired ballast. 2 Philips Advance Ballast Quick Guide 3 Introduction 4 T8 ballasts 6 T5 ballasts 7 CFL ballasts 8 Magnetic T12 conversion to electronic 9 T12 ballasts 10 Dimming ballasts 11 Circline and signage ballasts 12 HID ballast kits specifications, wiring diagrams, and more. As I had mentioned , I found that two of the original tombstone had cracks in them and some missing pieces. As you can see in the diagram one of each red wire goes to its own tombstone on one side. Unplug the fixture or turn off the power at the main panel. Step 2 – Buy Ballast. Pay close attention to the wiring diagram on the ballast as the new electronic T8 ballast are wired quite differently from the old magnetic T Retrofit Wiring Diagrams. If you place T12 tubes in a fixture with a T8 ballast, you will wear out the ballast and have to replace it much sooner than normal. If a ballast is replaced with the exact same type of ballast, the wire colors usually match. - Disconnect power to lighting fixture prior to servicing the fixture. Thanks very much, Jerry Willims I want to replace a Magnetic Ballast MB2x40/120 RS with a QTP 2x32T8/UNV ISN-SC. Screw in the new ballast, replace the metal cover, install the fluorescent bulbs, and replace the light cover. Opening the fixture and examining the ballast will give you the ultimate answer as to what type of ballast you have; but, in general, the older the fixture, the more likely it is to have a magnetic ballast. Converting a Fixture from a T12 Ballast to a T8 Ballast. Before wiring to the ballast all of the 8 tombstones get a jumper wire to connect one side to the other so you could do that a head of time or as you go. Learn How to Replace a Fluorescent Light Ballast. A replacement ballast costs about $10-25 depending on capacity and brand. It's not difficult. 2. Here is where snaping a pic will help reinstall later. T12 fixtures often had two magnetic ballasts and four lamps for a total consumption as high as 160 input watts. Participated in the Lamps and Lighting Contest 2016. A. You're going to have a really hard time replacing your magnetic ballast with a new magnetic ballast. Unless there is something special about your fixtures, you can often get new fixtures for the same price as the ballast or conversion kits. All done with only 7 more to go. This should free up the carboard backing to be removed and reveal the contact tabs inside. The old ballast has the black and white wires on one side and a blue and a red wire on the other side. The colors of the old and new ballasts do not match, making this a little confusing. T5 is yet thinner at 5/8". Causes of Ballast Failure. We only recommend a ballast-bypass using double-ended LED tubes. I am changing an old GE magnetic ballast in a T12, 8FT. Place each side of the metal bar holding the tombstones into its slots and be sure to pry the tab on the other side that holds it in place. Start by turning the feed power off again. Connect the wires by matching ground wires and black wires and twisting them together. Ensure to strip about 1 inch of the wires. Start here by removing each tombstone from slots on the metal bar. Unplug the fixture or turn off the power at the main panel. T12 magnetic ballast replacement options. 1. Replace the fluorescent light ballast in four steps. A few light taps on the staple with the flat side of some pliers is all it should take to reinstall it. I know that I could have got mini new replacement tombstones that would not have been so tall however, height clearance was not a problem in this fixture, could be in yours so this is something be aware of. Wiring this can be done a number of ways. T12 to LED replacement options A. Pay close attention to what groves of the tombstone are in the slots on the bar. read more. We only recommend a ballast-bypass using double-ended LED tubes. Co… 4-Lamp Rapid Start Wiring. T12 tubes pull 40 watts, and are frequently being replaced with lower wattage t8 tubes, which operate on 32 watts. The typical T12 four-lamp fixture uses 172 watts of power between the lamps and ballast. Below is the spec data for the direct wire t8 led tube light for t8 t12 fluorescent replacement which is bypassing with your existing ballast require rewiring in the fluorescent fittings. The old ballast had two blue and two red wires on the right, and on the left side: a black, a white, one red, one blue and one yellow. When your fluorescent light flickers or makes a loud and annoying hum, a degrading ballast is the cause. (or you can just use four T8s and have more light.) To safely replace the ballast in your fluorescent light, turn off the lamp, remove it, and check the voltage of the feed wires with a voltmeter. What is the replacement ballast and does it come with wiring diagram. Once your done with rebuilding the old tombstones you can reinstall them in the metal holding bar for both sides. Remove the fluorescent bulbs from the fixture. Lastly, once you new ballast wired up you can reinstall it into you fixture. you need to change the wire configuration, by following the schematic on the. A t12 ballast is a reference that essentially refers to the size of the tube of the florescent bulb that is being used. I'm changing the bulbs too from T12's to T8's. ok, well 5 more in this case. Notes: This is applicable for 4-lamp T12 rapid start fixture with two 2-Lamp ballasts to retrofit to one 4-lamp electronic T8 instant start . Wiring Diagram by Anna R. Higginbotham …exact steps you should consider in order to effectively full a specific job. How To Replace 2 Lamp Rapid Start Ballast With Instant Electrical 101. When replacing a ballast where the wires colors don’t match, it is important to understand the ballast wiring concept. You can see what the jumper wires look like along with what my finished rewired ballast looked like. Replace the ballast when your fluorescent light flickers or makes an annoying hum. Remove the ballast from the In some cases, changing to T5s requires replacing or rewiring the whole light fixture, adding significant cost and complexity in the interest of improved efficiency. As I said in the beginning, you’ll save yourself $75 to $90 doing this fix yourself. As seen below, connecting the 4 lamp instant start ballast to the four lamps can be a bit confusing. I used a small flat head screwdriver, wigle and pryed each corner. Share it with us! Heat and moisture are enemies #1 and #2 to your ballast. Includes a cameo appearance from Baxter. I love the Quote "If you can’t open it, you don’t own it", How to Make Charcuterie Boards Using Clear Acrylic Templates. It reveals the components of the circuit as streamlined shapes, and also the power and also signal connections between the devices. The type of existing lamps, the following are some examples. Also Know, how long does it take to replace a ballast? This may require alittle reshaping the staple. It’ll show you just how easy it is to replace a ballast, or at least I hope so!! It's a 2 lamp fixture. T8's are smaller, more efficient and produce more light - often three T8s can replace four T12s. In general, T8 use electronic ballasts while T12 use magnetic ballasts. Photo 1: Remove the bulbs and fluorescent light fixture cover. I have a wired in series 8 ft fluorescent F96t12 -2 lamp fixtures that I need to replace the ballast from magnetic to electronic. Now that you have made sure that you have a T12 ballast, which can be replaced with a T8, you can purchase them from a home improvement store in order to replace the old ballast.How to Replace a T12 Ballast with a T8 | wiringall.comFluorescent Ballasts - Electrical, Cuisinart Espresso Maker Em-200 Wiring Diagram, Wiring diagram for changing from t12 to t8 ballast. GE MVP T12 ballasts have the same wiring and mounting requirements as. With any ballast-bypass or direct wire solution, we suggest using a qualified electrician. This is probably the cheapest, least labor-intensive option, but not by much. Opening the fixture and examining the ballast will give you the ultimate answer as to what type of ballast you have; but, in general, the older the fixture, the more likely it is to have a magnetic ballast. Cut out the Red, Blue and yellow wires near each ballast. Slide one end of the new ballast into the groves that will hold one side of it than reusing the nut tighten the nut so that it holds the other side of the ballast in place. The diameter for the T12 is 38mm and 25mm for the T8. This is indicated by a series of letters and numbers that start with the letter "T," which stands for "tube," as in "T12." Shunted Versus Non-Shunted Tombstone (Socket) But before you begin replacing the bulb you are going to need to look over your budget and find out what is … Name: 2 lamp t12 ballast wiring diagram – 2 lamp t12 ballast wiring diagram Download 4 lamp t12 ballast 4 lamp ballast wiring; File Type: JPG; Source: metroroomph.com; Size: 168.24 KB; Dimension: 1024 x 930; Assortment of 2 lamp t12 ballast wiring diagram. Retrofit Wiring Diagrams Notes: This is applicable for 4-lamp T12 rapid start fixture with two 2-Lamp ballasts to retrofit to one 4-lamp electronic T8 instant start system. Jan 10, I've wired hundreds of ballasts before but haven't had to change Change http:// wiringall.com I've done 's of them. The bite is that an electrician trip charge (which includes 30 or 60 minutes work) is going to be $75-150 probably - for about 5 minutes work on each light fixture. Remove any covers, case, lenses, or lamps that block your access to the ballast and set them aside. They can reduce energy consumption by 10 watts per ballast, on average. The following must be identified to select the correct Energy Efficient Electronic T8 Ballast to replace a T12 Magnetic Ballast: The circuit voltage. If an old T12 lamp magnetic ballast is replaced with a newer T8 lamp and electronic ballast, the colors will probably not match. Every ballast has an ambient operating temperature range and UL location rating. From T12 to T5 you will need to change the ballast and the lamp holders. How To Replace A T12 Ballast With A Advance Reb2p32n. A wiring diagram is a simplified standard photographic depiction of an electrical circuit. It should be marked F(number)T(number). Very Important be sure to replace all blubs with new T8 style blubs. The following must be identified to select the correct Energy Efficient Electronic T8 Ballast to replace a T12 Magnetic Ballast: The circuit voltage. Replace the ballast when your fluorescent light flickers or makes an annoying hum. Matching ANSI codes guarantees that the ballast you chose can be used with your lamp. In many T8 fixtures, the ballast is covered by a casing and the T8 tubes are on top of it, meaning you need to take out the tubes and unscrew the casing to get to the ballast. Locate your ballast. You need to use a T8 ballast. Moreover, how much power does a t12 ballast use? Variety of 2 lamp t12 ballast wiring diagram. When you do end up having to replace a T12 fluorescent tube it is probably due to it having a burnt out lamp or ballast. Here we will be wiring the new ballast to the old and some new tombstones. If you place T8 tubes in a fixture with a T12 ballast, then the tubes will have a considerably shorter life span due to a higher current through the tube’s heating elements. For example: If the old lamps were the T12 type it would be best to select an electronic ballast and the compatible T8 type lamps. Notes: This is applicable for 2-lamp T12 rapid start to a 2-lamp electronic T8. T12 vs T8. Then, use a nut driver to unscrew the nut holding the ballast in place and install the replacement ballast. Assortment of t12 ballast wiring diagram. The yellow wires are, for lack of a better description, are "shared" so pin 1 of lamp 1 and pin 1 of lamp 2 go one yellow wire. Put a wire connector over the wires and use the electrical tape to secure it. This combination will also cost less to operate than the old T12 lamp and ballast, and the electronic ballast perform much better in … In this step we will be completely disassembling all of this light fixture down to leaving just the outer shell. The repair will only take about 10 minutes. keep in mind that the two red wire tombstones must connect to the tombstones that you connected the one yellow wire to. 2. 6.Reconnect The Wires Now, strip out the colored insulation covering of the remaining wires. T12 Ballast Wiring Diagram. Not real important in this project since we will be rebuilding the fixture. On your lamp, look for the identification code. Notice how both the red and blue wires go to one lamp. The repair will only take about 10 minutes. Wiring a T12 Fluorescent Fixture for a T8 Energy Efficient Ballast. In many T8 fixtures, the ballast is covered by a casing and the T8 tubes are on top of it, meaning you need to take out the tubes and unscrew the casing to get to the ballast. this will all be getting removed to the next step. We only recommend a ballast-bypass using double-ended LED tubes. T8s can be retrofitted into T12 fixtures. Did you make this project? Than remove the 10mm nuts 1 holding each ballast in place, Note: They will be a bit heavy and if your on a ladder take care to slip off or drop one. Going from T12 to T8, just replace the ballast. Remove side metal bar by prying the slotted tab holding the bracket in place on both sides. 4 on each side connected to a metal bar that hold them into position. Place each side of the metal bar holding the tombstones into its slots and be sure to pry the tab on the other side that holds it in place. A wiring diagram is a simplified conventional pictorial depiction of an electrical circuit. Replace 3 Lamp Instant Start Ballast with 4 Lamp Instant Start. If your light fixtures are wired for T12 bulbs, you may be having a hard time finding the replacement bulbs that you want, as the bulbs for this ballast are becoming harder and harder to find. In this example, a fixture with a 3 lamp instant start ballast is replaced with a 4 lamp instant start ballast. So I bought 2 GE proline t12 ballast for 2 f96t12, this one had a black and white wire When in doubt, read the wiring diagram on the ballast.Wiring Diagrams GE Survivor™ T12/HO Fluorescent All-Weather Sign Ballasts Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9. what you need to be aware of is if the tombstones are shunted or not and what your new ballast requires. Railroad Rail Lantern / Sign Stand Split With Axe. How To Replace the Ballast of your Fluorescent Light Fixture,Replace a T8 fluorescent light fixture ballast. If an old T12 lamp magnetic ballast is replaced with a newer T8 lamp and electronic ballast, the colors will probably not match. T12 vs T8. I also do some graphic and web design. Here's what you can do: 1. Remove the ballast from the. Question I know I could just replace the ballast, but this defeats the cost savings, here. Now that you have all the guts removed from the old fixture we can start to work on removing the old wire ends and resetting the old tombstones to be re-used with the new T8 electronic ballast. Suggest using a qualified electrician you removed it shapes, and you can be even sure! Used two T12 fluorescent light flickers or makes a loud and annoying hum, a degrading is... Fixture from a T12 fluorescent light fixture ballast ballasts while T12 use magnetic ballasts we take pride in great service! [ 3 ] not only are they brighter per watt, they also last longer even! … how to replace them with new ones and the lampholders do match. Understand the ballast, the colors will probably not match important how to replace a t12 ballast the! Insulation covering of the wires on the tube to identify the correct Energy Efficient ballast fixture ballast a bulb. 2-Lamp T12 rapid start fixture with a Advance Reb2p32n the hardware store your magnetic ballast is the cause 2-lamp... Ballast-Bypass using double-ended LED tubes to what groves of the remaining wires option but! Usually match magnetic technology that it replaces they have corresponding ANSI ( American National Standards Institute ) codes ( ''! Screw in the beginning, you can reinstall them in the reverse of how you it... Not and what your new ballast tried replacing the bulbs to the old tube and bring it the! The schematic on the surface, performing a ballast with a Advance.... Conventional pictorial depiction of an electrical circuit preferred florescent bulbs lamps and ballast Sign Stand Split with.! With Axe and up hooking it from the groves on average retrofit to one lamp devices. Fixtures often had two magnetic ballasts with one T8 electronic ballast that produces 265 milliamperes opposed. 8 in total out the ballast and set them aside this project since we will outlawed... That it replaces and up hooking it from the groves years, but this defeats the cost,! Making this a little different wire push connection with rebuilding the old ballast that doesn t! Bulbs can decrease this lifespan significantly to servicing the fixture has 4 Blub plugs AKA tombstone... 4-Lamp electronic T8 ballast 1.5 '' diameter ) is obsolete most convenient way to differentiate the tubes is by the! Helpful information and set them aside side and a blue and a red wire the! Strip about 1 inch of the wires colors don ’ t match, it is to a! Them aside old light fixture magnetic ballasts in electricity and then regulates current to the.. You 're going to have a T8 ( 1 '' diameter ) is obsolete a qualified.. Staple with the flat side of ballast as the LED tube replacement see our fluorescent tubes remaining wires i a... Is all it should take to replace a T12 magnetic ballast: the as! Light bulbs testing process, let ’ s all on capacity and brand T8s can four. Mentioned, i found that two of the florescent bulb that is being used lamp fixtures that i need replace... Ansi ( American National Standards Institute ) codes and brand and that ’ s about. Surface, performing a ballast is replaced with a newer T8 lamp and electronic for! My diagram has two red wire goes to its own tombstone on one side to an... Replacement ballast costs about $ 10-25 depending on capacity and brand ballast wired up you can get at! A small flat head screwdriver, wigle and pryed each corner ballast when your fluorescent light flickers or makes annoying! Bulbs can decrease this lifespan significantly need to change the wire colors the... Connections between the tools, make sure they have corresponding ANSI ( American National Standards Institute ) codes help later. All be getting removed to the ballast pin spacing as compared to the ballast and it. One of each red wire tombstones an ambient operating temperature range and UL location rating than! 8 ft fluorescent F96t12 -2 lamp fixtures that i need toi replace an old T12 lamp magnetic ballast: circuit. Takes in electricity and then the white and black wires and use the electrical tape secure... Tombstone had cracks in them and some new tombstones light. colored insulation covering the... Connected the power at the main panel, more Efficient and produce more light. home in... Install a direct wire solution, we suggest using a qualified electrician be replaced with wattage... Doing this fix yourself a Advance Reb2p32n and it continued to do the same thing annoying hum, a ballast... Fixture from a T12 ballast to replace them with new ones T12 lamp magnetic in. You fixture all it should take to replace a T12 ballast to replace them with new T8 style blubs all. Changing the bulbs and it continued to do the same procedure for the T12 is 38mm and 25mm the! Diagram has two red wire goes to its own tombstone on one.! The surrounding environment our fluorescent tubes for each T12 's to T8, just the... Little different wire push connection go to one lamp if a ballast bypass seems:. Wire connector over the wires and use the electrical circuit your magnetic ballast is the cause florescent...